The Agilent 8714ET features a built-in transmission/reflection test set
with a full range of magnitude and phase measurements. Two independent
channels can measure and display two device parameters, such as
transmission and reflection response, in a variety of formats including
complex impedance, SWR, and delay, on rectangular, polar or Smith-chart
displays. These analyzers also employ advanced vector-error-correction
techniques to enhance measurement accuracy.
For a wider range of
output power levels to test active devices and components, Option 1E1
adds a 60-dB step attenuator as a standard feature, which extends the
lowest power-level setting to -60 dBm. Both 50-ohm and 75-ohm versions
are available.
View the ENA Series of RF Network Analyzers
product overview and application examples online: ENA Series RF Network
Analyzer Video Demos
Principais recursos e especificações• Narrowband and broadband detection
• 100 dB dynamic range
• Real-time sweep speeds (40 ms/sweep)
• Integrated T/R test set
• Synthesized source with 1-Hz resolution
• Standard LAN interface
• Standard Internal Agilent Instrument BASIC (IBASIC)
• Standard 2, 6, and 12-port switching test sets available
Frequency
Range:
| 300 kHz to 3.0 GHz |
Resolution:
| 1 Hz |
Stability:
| ±5 ppm, 0° to 55° C, typical |
CW Accuracy: | ±5 ppm, 25° ±5° C <1 Hz with 10% change in line voltage, typical |
Signal Purity
Harmonics:
|
| <-30 dBc |
Nonharmonic Spurious:
| <50 kHz from carrier >50 kHz from carrier
| <-25 dBc, characteristic <-30 dBc, characteristic |
Phase Noise (at 10 kHz offset):
|
| <-67 dBc/Hz, characteristic |
Residual AM (in 100 kHz bandwidth):
|
| <-50 dBc, nominal |
Residual FM (30 Hz to 15 kHz): |
| <1.5 kHz peak, nomina |